FE Electrical exam · Section 10 · Power Systems
AC power and power factor: real, reactive and apparent power, worked example
AC power has three parts. Real power does the work. Reactive power moves back and forth between the source and the load's inductance or capacitance. Apparent power is what the wires have to carry. Power factor is the share of apparent power that is real.
- Power Systems: 8–12 of 110 exam questions
- 1 worked example · 2 practice problems
How it works
Use rms voltage and current. If the current lags the voltage by an angle , only the in-phase part of the current delivers net energy.
The three powers form a right triangle, so any two of them give the third. For a load given as an impedance , the angle of the impedance is the power-factor angle.
A lagging power factor means an inductive load, with positive Q. Leading means capacitive. A capacitor placed across an inductive load supplies some or all of its reactive power.
The formulas you need
- Real power, in watts
- Reactive power, in var
- Apparent power, in VA
- Power factor
- Reactive power of a capacitor
Worked example
The problem
A 240 V rms, 60 Hz source feeds a load of . Find the current, the power factor, and the real, reactive and apparent power. Then find the capacitor, connected across the load, that brings the power factor to unity, and the new source current.
- Source
- 240 V rms, 60 Hz
- Load
- 8 + j6 Ω
- Target
- unity power factor
Step 1: Current
Step 2: Power factor
The reactance is positive, so the load is inductive and the current lags.
Step 3: The three powers
Step 4: Capacitor for unity power factor
It must supply all 3,456 var.
Step 5: New source current
The source now supplies real power only.
Answer
24 A at 0.80 power factor lagging, with 4,608 W, 3,456 var and 5,760 VA. A 159 µF capacitor brings the power factor to unity and the source current down to 19.2 A.
Common mistakes
- Using peak values. The power formulas need rms voltage and current.
- Adding P and Q like ordinary numbers. 4,608 plus 3,456 is not the apparent power. They add at right angles.
- Getting lead and lag the wrong way round. An inductive load lags.
Practice problems
Work each one on paper first, then open the answer.
1. A load draws 10 A from a 120 V rms source at 0.60 power factor lagging. Find P and Q.
Show the answerHide the answer
720 W and 960 var
W. With , , so var.
2. A load has S = 5 kVA and P = 4 kW. Find Q and the power factor.
Show the answerHide the answer
3 kvar and 0.80
kvar and .
FE Electrical course · Lesson 10.1 · 6 min
Watch this topic as a video lesson
Lesson 10.1, Single-phase power and power factor, is part of the FE Electrical Exam Pass. The first section of the course is free with a VoltIQ account, so you can try the lessons before you pay anything.
- A 6-minute animated video that walks through the topic step by step
- Five practice questions with worked solutions
Keep going
Not sure where you stand? The free FE Electrical diagnostic has 17 questions, scored by topic, with an explanation for each.
Take the diagnosticWritten by VoltIQ Academy for exam preparation. The example and practice problems are our own. VoltIQ Academy is not affiliated with or endorsed by NCEES. This page is study material, not design guidance for a real installation.